News

Troubleshooting Common Faults Of Auxiliary Equipment

Jan 14, 2026 Leave a message

Troubleshooting Common Faults of Key Auxiliary Equipment

1. Feeding System (Loss-in-Weight Feeder, Volumetric Feeder, Side Feeder)
Fault Phenomena: Fluctuating output, inaccurate proportioning, unstable extruder current.
Common Causes and Troubleshooting:
Material Bridging/Caking: Check the material flowability in the hopper, and clean the material or install an arch breaking device.
Screw or Motor Malfunctions: Inspect if the feeding screw is jammed by foreign objects, if the bearings are damaged, and if the drive motor is running smoothly.
Load Cell Failure: Check if the load cell is covered with accumulated material affecting weighing accuracy and if the wiring is intact, then perform zero calibration.
Improper Parameter Settings: Verify if the PID control parameters match the characteristics of the current material.

 

2. Temperature Control System (Heating Coils, Cooling Fans, Oil Temperature Units, Water Chillers)
Fault Phenomena: Severe temperature fluctuations, difficulty in continuous heating or cooling, cold slug or thermal decomposition in products.
Common Causes and Troubleshooting:
Heater Malfunction: Measure the resistance of heating coils with a multimeter to determine if an open circuit has occurred.
Cooling Channel Blockage: Check if the pipelines, valves and filters of water/oil cooling systems are unobstructed.
Thermocouple Damage or Misalignment: Inspect if thermocouple wiring is secure and if the measuring end is tightly attached to the measurement point, or replace the thermocouple for testing.
Temperature Control Module/PID Malfunction: Verify if the output of the temperature controller is normal and readjust the PID parameters.

 

3. Melt Processing Units (Screen Changers, Melt Pumps, Static Mixers)
Fault Phenomena: Abnormal fluctuations in melt pressure (sudden increase or decrease), presence of impurities or streaks in products.
Common Causes and Troubleshooting:
Screen Changer Clogging: This is the most common cause of elevated melt pressure; the filter screen must be replaced in accordance with procedures.
Melt Pump Malfunction: Inspect the gear wear of the gear pump, check for damaged bearings, and verify the alignment of the coupling.
Seal Leakage: Examine the sealing surfaces at the connections of screen changers, melt pumps, die heads, etc., for damage, and check if the fastening bolts are loose.

 

4. Other Auxiliary Systems
Pelletizing System: Uneven pellet size, agglomerated pellets, incomplete cutting. Inspect the sharpness of the cutting blades, the gap between the moving and fixed blades, and the matching of pelletizing water temperature and rotational speed.
Drying/Conveying System: High material moisture content, poor conveying performance. Check if the desiccant has failed, verify the drying temperature and air volume, and inspect the conveying pipeline for blockages or air leaks.

Send Inquiry